FIELD
TITLE and DATA ENTRIES
Misc. Fault Delay Time
*87
0 = 15 secs
1 = 30 secs
2 = 45 secs
3 = 60 secs
4 = 90 secs
5 = 2 min
*88
Exit Options
0 = all intrusion zones must be intact before
arming
1 = All intrusion zones except in exit path (zone
list 12) must be intact before arming. Will go
into alarm if not restored at end of exit time
2 = All intrusion zones except in exit path (zone
list 12) must be intact before arming. Will be
bypassed if not restored at end of exit time
3 = Final contact set: All intrusion zones except
in exit path (zone list 12) must be intact
before arming. Once armed, exit delay
remains on indefinitely until the last zone,
as defined in zone list 8, is restored; then
there is 5-second exit delay before arming
state is active
Event Log Full Report Code
*89
0 = disable; 1-F = see description above ∗59
Event Log Enables
*90
0 = no event logging
1 = log Alarm/Alarm Restore
2 = log Trouble/Trouble Restore
4 = log Bypass/Bypass Restore
8 = log Open/Close
x = log combination of events (add value of
entries)
6 = 2-1/2 min #+12 = 8 min
7 = 3 min
#+13 = 10 min
8 = 4 min
#+14 = 12 min
9 = 5 min
#+15 = 15 min
#+10 = 6 min
#+11 = 7 min
EXPLANATION
Used with zones assigned to a configurable zone
type with fault delay on (selected in alarm/trouble
processing prompt), and sets a zone response time
of 15 seconds to 15 min. It can be assigned to zones
with sensors that provide a trouble indication when
an oil or gas tank is low, or similar applications for
critical condition monitoring where a non-alarm
response is desired and where the zone response
time should be very long to avoid reacting to
normal transient faults.
Select the desired option.
NOTE: Must be "0" if system uses zone type 82 -
Blockschloss.
If an Event Logging selection is made in field ∗90, a
message can be sent to the central station receiver
when the log is 80% full. If the log becomes full,
new messages overwrite the oldest messages in the
log.
This system has the ability to record up to 254
events in a history log. At any time, the downloader
operator can then upload the log and view or print
out all or selected categories of the log. The
downloader operator can also clear the log. Event
log can also be viewed at an alpha keypad (see User
Guide for log display format).
The display/printout at the central station will
show the date, time, event, and description of the
occurrences.
Data Entry Example: To select Alarm/Alarm
Restore" and "Open/Close", enter 9 (1+ 8); to select
all events, enter #15.
Data Field Programming
4-11