PROMPT
L
01
02
03 04
T
23
22
21 23
PARTITION
1
ENTER START ZONE
00 = QUIT
36
INPUT S/N
L
AXXX-XXXX
VALID ENTRIES
Template Display
[∗] to continue
Partition
1 = partition 1
2 = partition 2
3 = partition 3
[∗] to continue
Start Zone Number
[∗] to continue
Serial Number
[∗] to continue
Menu Mode Programming
EXPLANATION
4. When [∗] is pressed, the selected template will
be displayed.
Top line of display represents loop numbers,
bottom line represents zone type assigned for
each loop.
5. Press [∗] to accept template.
6. Enter the partition in which the key is to be
active.
7. Press [∗] to continue.
8. The system will search for the highest
available consecutive 4-zone group (the four
zones in the case of the 5804 and 5804BD), and
display the lowest zone number of the group.
If you want to start at a different zone, enter
the zone desired, and press [∗]. If that zone
number is displayed, the system has the
required number of consecutive zones
available, beginning with the zone you
entered. If not, the system will again display a
suggested zone that can be used.
If the required number of consecutive zones is
not available at all, the system will display
"00".
9. Press [∗] to accept.
10. Manually enter the serial number printed on
the label for the wireless key or press and
release the button to transmit its serial
number.
11. Press [∗] to accept the serial number. The
system will check for duplicate.
12. If necessary, press the [#] key to back up
without saving, and re-enter the serial
number.
Use the [A] key to move forward within the
screen, and the [B] key to move backward.