FIELD
TITLE and DATA ENTRIES
Miscellaneous Options
*91
Entry 1 – AAV and Exit Delay Restart:
0 = none
4 = using Audio Alarm Verification (AAV) unit
8 = Enable Exit delay restart/reset ††
Multiple choice example: for both AAV and Exit delay
restart, enter # + 12 (4 + 8).
Entry 2 – Output Activation Commands:
0 = allow keypad output activation commands
(user code + # + 7 and user code + # + 8)
1 = do not allow keypad output activation commands
Telecom Monitor Enable
*92
Entry 1–Timeout:
0 = disabled
1-15 = 1 minute to 15 minutes respectively
(2 = 2 min, 3 = 3 min, etc.; # + 10 =10 min, # + 11 =
11 min, # + 12 = 12 min, # + 13 = 13 min, # + 14 = 14
min, # + 15 = 15 min)
Entry 2–Display/Sound:
0 = keypad display only when phone line is faulted.
1 = keypad display plus keypad trouble sound when
line is faulted. Each partition turns off its own
trouble sound. No automatic timeout.
2 = Same as "1" plus programmed output device
STARTS. If any partition is armed, external
sounder activates. External sounder will be
turned off by normal siren timeout or by security
code plus OFF from any partition (it does not
have to be the one that was armed).
No. of Reports In Armed Period
*93
per Zone (Intermittent Sensor
Suppression)
0 = unlimited number of reports
1 – 6 = 1 – 6 report pairs per zone per armed period
4-12
EXPLANATION
Entry 1:
Select the desired options by adding the values of
each desired option.
††"Exit Delay Restart/reset" option allows use of
the [∗] key to restart the exit delay at any time
when the system is armed STAY or INSTANT.
This feature also enables automatic exit delay
reset, which resets exit delay if the entry/exit door
is re-opened and closed before exit delay time
expires after arming AWAY or MAXIMUM.
Entry 2: Select whether to allow outputs to be
activated by the keypad activation commands (user
code + # + 7 and user code + # + 8).
IMPORTANT: AAV should not be used when
Paging or Alarm Reports are sent to a secondary
number unless the monitoring zone option is used
(which pauses calls). Otherwise, the call to the
secondary number by the communicator after the
alarm report will prevent the AAV from taking
control of the telephone line, and the AAV "Listen
in" session cannot take place.
Entry 1: Sets the length of time a phone line fault
must remain after detected before the second digit
option is activated.
Entry 2: Selects the desired phone line fault
response.
Option 2 may be used even if a relay unit or
Powerline carrier device is not connected to the
control.
Programmed Output Device must either be
programmed to be STOPPED in field ∗80 or
STOPPED by entry of [security code] + [#] + 8 +
device number. Partition in ∗80 should be set to
"0," for STOP.
This option can be used to limit the number of
alarm/alarm restore messages per zone sent to the
central station in an armed period.