Installation and Setup Guide

Compatible Devices

Supports up to 8 Addressable Keypads: 6148/6150 Fixed-Word Display Keypads, 6164 Alpha
Keypad, 6128RF/6128RFH/6150RF/6160RF Keypad/Transceivers, 6160V Voice Keypad
Supports up to two (2) Touch Screen (AUI) Devices (Symphony, 6270), which are in addition to
the standard eight (8) addressable keypads.
Supports a 4219 or 4229 addressable basic wired zone expander module
Supports 5881/5883 series receiver and 5800 series transmitters
Outputs up to 4 relays, two on-board triggers, and/or Powerline Carrier Devices (X-10 type)
-- Use any combination of 4204, 4229, 6164 relays and/or Powerline Carrier Devices.
-- Output functions (up to 12)
Alarm power output provides a 12VDC, 2 AMP output that can drive compatible sounders with
a steady output for burglary/panic, or temporal pulse (3 pulses – pause – 3 pulses – pause – 3
pulses.) for fire. Uses current limiting circuitry for protection.
Auxiliary Power Output: 12VDC, 700mA maximum, including output triggers.
Backup Battery: Rechargeable (sealed lead-acid type) 12VDC, 6AH minimum.
Audio Alarm Verification (using AAV module, such as ADEMCO UVS); can be used in
conjunction with an output trigger to permit voice dialog between an operator at the central
station and a person at the premises.
Alternative Communication Media: Primary telephone number messages can be reported via
ECP connection to Ethernet TCP-IP Internet/Intranet Network Modules, or other network
interfaces (e.g., EUREKA)
AC Power Supply:
VISTA-12A: Plug-in 230VAC power pack, XF1 Model No. 60844CK, Ap11V/99090/E148-36
VISTA-12E: 220VAC wired-in transformer, 16.5VAC 25VA

Important Installation Highlights (Installer Please Read)

This system uses addressable keypads and a Zone Expander Module (see table of addresses in
Programming Overview section).
Keypads must be set for addresses 16-23 (first keypad is address 16, which is different from
previous controls) and programmed in data fields *190-*196.
Zone Expander Module must be set for specific address (08), based on the zone numbers used
(see table of addresses in 4219/4229 Expansion Zones section).
4204 Relay Module must be set for specific address (13; see Connecting Relay Modules section).
6164 Keypads must be set for two addresses: a keypad address and a zone expander address (if
using the keypad's expansion zones).
This control will not power-up unless AC mains is connected (will not power-up on battery
alone). However, once the system is powered up, it will operate on battery power in the event
of AC mains loss.
Relays have two programming menu modes: Use *79 Menu mode to map module addresses
and device (output) numbers. Use *80 Menu mode to define the output functions (see Output
Device Programming section).
This system supports programmable function keys. Use *57 Menu mode to define the function
keys (see Function Key Programming section).
This system provides various paging features. Refer to the Programming Overview section
for a summary on pager programming.