FIELD
TITLE and DATA ENTRIES
Exit Time Display Interval
*197
0 = no display
1-5 = seconds between display refreshing
Display Partition Number
*198
0 = no
1 = yes
ECP Device Fail Display
*199
0 = 3-digit display ("1" + device address)
1 = 2-digit fixed-display as "91"
4-20
EXPLANATION
If enabled, keypads display the exit delay time
remaining after arming the system, with display
updates at the interval selected (i.e. if the exit delay
is 30 seconds and "2" is selected in this field, the
keypad display refreshes every 2 seconds, displaying
30, 28, 26, 24, etc.).
An interval greater than "1" may be necessary for
some older keypads to allow users time to enter key
presses between display updates.
If selected, the partition number is displayed in the
upper-left corner of the display. This is useful when
using the GOTO partition function.
Select "0" if using Alpha keypads and/or 3-digit
Fixed-Word Display keypads (6148, 6150, 6160,
6164). ECP faults for keypads and/or other
peripheral ECP devices will display "1" plus the
device address (00-30) of device causing the fault
(e.g., faults on device 07 display as "107").
Select "1" if using 2-digit Fixed-Word Display
keypads (e.g., certain 6128RF series keypads). If
selected, ECP faults for keypads and/or peripheral
devices will display as "91" on 2-digit displays, and
"191" on 3-digit or Alpha keypads.