Installation and Setup Guide
PROMPT
Zn ZT P RC
In: L
17 00 1 10
RF: 1
OR
Zn ZT P RC
In: AD
17 00 1 10
AW: 07
OR
Zn ZT P RC
HW: RT
17 00 1 10
EL
1
17 Zone Type
Perimeter
03
17 Partition
1
17 Report Code
1st 01 2nd 00 10
17 HARDWIRE TYPE
EOL
0
5-2
VALID ENTRIES
Summary Screen
[∗] to continue
Zone Type (ZT)
00-24, 77, 82, 90-93 = zone
type (see table at right)
Partition No. (P)
1-3 = partition
[∗] to continue
Report Code (RC)
First Digit: 01-09, 10 for A, 11
for B, 12 for C, 13 for
D, 14 for E, 15 for F
00 to disable
Second Digit: same as above
[∗] to continue
Basic Wired Type
0 = EOL; 1 = NC; 2 = NO
3 = zone doubling (ZB)
4 = double-balanced (DB)
[∗] to continue
EXPLANATION
A summary display appears.
"IN: L" appears for wireless zones and indicates
input type and loop.
"IN: AD" appears for wired expansion zones (AW)
and indicates the module's address (AD), which is
based on the zone number.
"HW: RT" appears for basic wired zones and
indicates configuration (EOL, NO, NC, zone
doubling, double-balanced) and response time
selection.
Each zone must be assigned to a zone type, which
defines the way in which the system responds to
faults in that zone.
Enter the Zone Type code from the list below:
Note: If 00 is entered, Delete Zone ? will be
displayed.
00 = Not used
01 = Entry/exit #1
02 = Entry/exit #2
03 = Perimeter
04 = Interior Follower
05 = Trouble
Day/Alarm Night
06 = 24-Hr Silent
07 = 24-Hr Audible
08 = 24-Hr Aux
09 = Fire
10 = Interior w/Delay
12 = Monitor Zone
*5800 button-type
transmitters only
Enter the Partition number for this zone.
Partition 1 is shown entered. (3 = Common
Partition).
Enter the report code for this zone, which consists of 2
hexadecimal digits, each in turn consisting of 2
numerical digits. For example, for a report code of
"10," enter 01 and 00.
®
For Contact ID
, entering any non-zero entry as the
first digit enables the report code for this zone. Refer
to the System Communication section for
information about report codes and formats.
This prompt appears only for zone numbers 01-06.
Zone 1 is automatically set for EOL operation.
14 = Gas
15 = Medical
16 = Fire w/Verify
20 = Arm–STAY*
21 = Arm–AWAY*
22 = Disarm*
23 = No Alarm Resp
24 = Silent Burglary
77 = Keyswitch
81 = AAV Monitor
Zone
82 = Blockschloss
90-93 = Configurable