Honeywell ADEMCO VISTA-12A Installation And Setup Manual page 38

Hide thumbs Also See for ADEMCO VISTA-12A:
Table of Contents

Advertisement

Installation and Setup Guide
FIELD
TITLE and DATA ENTRIES
Arming Prevention Override
*25
Entry 1: 0 = no arming prevention override
1 = allow system to arm with an RF
supervision failure
2 = allow system to be armed with an
AC Mains Loss
4 = allow system to be armed with a
system low battery
Entry 2: 0 = no tamper override
1
= allow system to be armed with a
tamper fault
2
= allow system to be armed with a
tamper fault once
Chime By Zone List 3
*26
0 = no zone list (chimes on fault of any entry/exit
or perimeter zone when chime mode on)
1 = use zone list (chimes on fault of specific
zones programmed in zone list 3 when
Chime mode on)
Powerline Carrier Device (X-10) House
*27
ID
0 = A
1 = B
2 = C
3 = D
4 = E
5 = F
ECP Contact ID Output for ACM
*29
0 = not used
1 = use Contact ID output on ECP
4-2
6 = G
# + 11 = L
7 = H
# + 12 = M
8 = I
# + 13 = N
9 = J
# + 14 = O
# + 10 = K
# + 15 = P
EXPLANATION
If no override is selected, system will not be able to
be armed when there is either a supervision
failure, system low battery, AC mains loss, or a
tamper condition.
If override is enabled, the user must enter the
arming sequence twice to arm the system; the first
entry of user code + arm command will not arm,
but a second entry of user code +arm command will
arm the system.
E.g., To select arm with "supervision failure" and
"low battery", enter 5 (1 + 4)
† NOTE: If tamper option 1 or 2 is selected, field
*175 digit 2 must be "0."
If enabled, you can define the specific zones
intended to chime when faulted while the system is
in Chime mode. Use zone list 3 to assign these
zones (see ∗81 Zone List Programming section
for details).
Powerline Carrier devices require a House ID,
identified in this field. Program Powerline Carrier
devices in interactive modes ∗79, *80 and *81.
If selected, all messages programmed to go to the
primary telephone line receiver will also be sent to
the connected Alternative Communication Media
(ACM), such as a 7845i Internet/Intranet
Communicator or AI4164RS/AI4164ETH Eureka
Network Interface (sent in Contact ID format). The
data line is supervised as well as certain functions
in a long range radio. If communication is lost or a
trouble develops, an attempt will be made to send a
message via both ACM and telephone to the central
station.
Program the ACM for device address 3.