FIELD
TITLE and DATA ENTRIES
Burglary Dialer Delay
*50
0 = no dial delay
1 = 15 seconds
2 = 30 seconds
3 = 45 seconds
Common Partition Primary Subs. Acct.
*51
No.
Enter digits 0–9; # + 11 for B, # + 12 for C, # +
13 for D, # + 14 for E, # + 15 for F.
Common Partition Secondary Subs.
*52
Acct. No.
Enter digits 0–9; # + 11 for B, # + 12 for C, # +
13 for D, # + 14 for E, # + 15 for F.
SESCOA/Radionics Select/
*53
CID Codes
SESCOA/Radionics:
0 = Radionics (0-9, B-F reporting)
1 = SESCOA (0-9 only reporting)
Contact ID Codes:
0 = disable both Time/Date Inaccurate and
Successful Download/Access reports
1 = enable Time/Date Inaccurate report (code
626);
2 = enable Successful Download/Access
report (code 412)
3 = enable both Time/Date Inaccurate and
Successful Download/Access
Dynamic Signaling Delay
*54
0 = disabled (both signals sent)
1–15 = entry times a 15-second delay.
e.g., 1 = 15 seconds, 2 = 30 seconds, etc.
4-6
EXPLANATION
Provides delay of "BURGLARY ALARM" report to
the central station, which allows time for the
subscriber to avoid a false alarm transmission. This
delay does not apply to zone type 24 alarms (silent
burglary) or to 24-hour zone types 6, 7, and 8 (silent
panic, audible alarm, auxiliary alarm), which are
always sent as soon as they occur.
Enter up to 10 digits, depending on the report
format selected in field *48.
Enter up to 10 digits, depending on the report
format selected in field *48.
SESCOA/Radionics:
Select SESCOA or Radionics format.
Select 0 for all other formats.
Contact ID (CID) Codes: If desired, enable the
Time/Date Inaccurate and/or Successful
Download/Access report codes. These reports are
valid only when Contact ID reporting format is used.
Intended for use with ECP Contact ID Output
reporting via ACM.
This field lets you select the time the panel should
wait for acknowledgment from the first reporting
destination (see ∗55) before it attempts to send a
message to the second destination. Delays can be
selected from 0 to 225 seconds, in 15-second
increments. This delay is per message. If "0" is
entered in this field, the control panel will send
redundant reports to both Primary Dialer and ECP
output.