9.6.3 Deactivate Remote Control Thermostat
Operation
The thermostat operation function on the remote control can be
deactivated. The remote control will still operate the main burner
on and off, and function flame, fan, and light modulation. To
deactivate this function,
1.
Verify all (3) AAA type batteries are installed in the remote
control.
2.
Remove one AAA battery.
3.
While re-inserting the AAA battery, push and hold down the
thermostat key. The temperature bulb graphic will not appear
on the remote control LCD screen.
To re-activate thermostat operation, follow the same button
sequence procedure described above. The temperature bulb
graphic will reappear on the remote control LCD screen.
Figure 9.8
9.7 Continuous Pilot / Intermittent
Pilot (IPI/CPI) Selection
This system has the option of a continuous (standing) pilot
feature. This allows you to change from a spark-to-pilot system to
a standing pilot system during cold weather conditions. By having
the pilot on continuously, the firebox will remain warm and a draft
is established in the vent that allows the main burner to turn on
with less air-flow disruption.
1.
A snowflake icon is visible during the setup of either IPI or
CPI modes when the system is OFF. To select the preferred
pilot ignition feature,
2.
With system in OFF position, press the mode key to index to
CPI mode icon.
3.
Press the up arrow key to activate CPI.
4.
Press the down arrow key to return to IPI. A single 'beep' will
confirm the reception of the command.
When the system is ON,
IPI mode - the snowflake icon is not visible on LCD screen.
CPI mode - the snowflake icon is visible on LCD screen.
Figure 9.9

9.8 Fan Speed Control

Fan speed can be adjusted through six (6) speeds. A single
'beep' will confirm reception of the command. To activate this
function,
Press the mode key to index to the fan control icon.
Press the up or down arrow keys to turn on, off, or to adjust
fan speed.
Thermostat Mode: Fan(s) have a five (5) minute delay time when
fireplace is lit, allowing time for heat to build in fireplace before
operating. The fan will continue to operate for approximately
twelve (12) minutes after fireplace has been turned off.
Manual Mode: Fan(s) will operate at previous setting. There is
no delay in start up or stop time.
Figure 9.10

9.9 Accent Light Kit

The light intensity can be adjusted through six (6) levels. A single
'beep' will confirm reception of the command.
1.
Press the mode key to index to light icon.
2.
Press the up or down arrow keys to adjust the intensity level.
Figure 9.11

9.10 Low Battery Detection

9.10.1 Remote Control
Remote control battery lifespan depends on various factors
including battery quality, number of ignitions, changes to room
thermostat set point, etc.
When the remote control batteries are low, a battery icon will
appear on the LCD display before all battery power is lost.
When batteries are replaced, this icon will disappear.