Page: 57
Service Guide PM3410
Chapter 3 Maintenance & Disassembly
3.2.23 Ribbon Feed Assembly
(3.2.19).
1. Remove the ribbon cartridge bracket
2. Remove the two mounting screws (1) and detach the ribbon feed assembly (2).
NOTE:
When assembling, install the ribbon drive assembly so that the gear backlash (3) is at a minimum.
P/N 50054301 Assembly: Ribbon Feed RSPL B.2.06
Copyright 1997, Okidata, Division of OKI America, Inc. All rights reserved. See the OKIDATA Business