Page: 106
Service Guide PM3410
Chapter 4 Failure & Repair Analysis
RAP 05: Ribbon Feed Problem
START.
Remove the ribbon cartridge.
Rotate the ribbon cartridge ribbon feed knob.
Does it rotate smoothly?
NO Has the lock mechanism on the ribbon been disengaged?
YES Replace the ribbon cartridge.
NO Disengage the lock mechanism.
YES Replace the ribbon. Slide the carriage from the left to the right.
Does the ribbon feed shaft rotate?
NO Replace the ribbon feed assembly.
YES Verify that the ribbon feed shaft is correctly engaged with the ribbon feed roller of the ribbon
cartridge.
Copyright 1997, Okidata, Division of OKI America, Inc. All rights reserved. See the OKIDATA Business