The Command and Response tables list valid ASCII (for Telnet or RS-232) command
codes, the corresponding URL (Uniform Resource Locator) encoded (for Web browsers)
command codes, the DMP 64 responses to the host, and a description of the command
function or the results of executing the command.
Symbol definitions
=
]
}
=
=
=
|
*
=
E
=
NOTE: For Web encoding only: data is directed to the specified port and must be
encoded (URL encoding) if it is non-alphanumeric. Change any non-alphanumeric
character (%, +, | , } , and so on) within the data section into the corresponding
hexadecimal equivalent, %xx, where xx represents the two-character hex byte. For
example, a space (hex: 20) would be encoded as %20 and a plus sign (hex: 2B)
would be encoded as %2B.

Error Responses

When the DMP 64 is unable to execute the command, it returns an error response to the
host. The error response codes and their descriptions are as follows:
E01 - Invalid input number (number is too large)
E12 - Invalid port number
E13 - Invalid parameter (number is out of range)
E14 - Not valid for this configuration
E17 - System timed out
E22 - Busy
CR/LF (carriage return/line feed) (hex
Carriage return (no line feed, hex 0D)
(for URL-encoded commands, use the pipe character,
instead)
%20
Space character (
for web browser)
Pipe (vertical bar) character
Asterisk character (which is a command character, not a
variable)
1B
Escape key (hex
)
(use W instead of Esc for Web browsers)
0D 0A
)
|
,
E23 - Checksum error (for file uploads)
E24 - Privilege violation
E25 - Device is not present
E26 - Maximum connections
exceeded
E27 - Invalid event number
E28 - Bad filename or file not found