Barco Trace+ R9040341 Owner's Manual page 50

Trace+
Table of Contents

Advertisement

6. Random Access
Vertical Start
Read AMDS
How to install the correct settings for the options in the Edit file menu.
EDIT FILE OPTIONS
Source number
Clamp position
Clamp delay
Clamp width
Field select
Vertical refresh
Vertical sync polarity
Select with ↑ or ↓
<ENTER> to toggle
↑ or ↓ to change value
<EXIT> to return
Menu 6-15
Source number
Clamp position
Clamp delay
Clamp width
Sync
pulse
Clamp
pulse
Image 6-2
Example for Clamp position [trailing]
46
number of lines between the start of the input signal and start of the image on
the screen.
AMDS = automatic mode detection & synchronization
During the installation of a file with LOAD, the system automatically measured the
horizontal period, the total vertical lines and the interlaced mode. When selecting
Read AMDS, the system remeasures the above indicated items.
1
[leading]
0
10
[both]
[sync]
[leading]
The source number of a non-active source can be changed to any other source number. This makes
it possible to create a file for future source numbers.
Clamping determines the black level of the signal. The clamp pulse can be related to the leading or
the trailing edge of the sync pulse. Use the ENTER key to toggle between [leading] and [trailing].
The time between the leading edge of the clamp pulse and the locked edge of the sync pulse. Can be
any value between 0 and 255. Change the value by pushing the cursor key ↑ or ↓.
The width of the clamp pulse can be any value between 0 and 255. Change the value by pushing
the cursor key ↑ or ↓.
Clamp
Clamp
delay
width
R5976781 TRACE+ 14/09/2004