Constant Light Output (Clo) - Barco Trace+ R9040341 Owner's Manual

Trace+
Table of Contents

Advertisement

How to Start Up the Lamp Menu?
1. Push the cursor key ↑ or ↓ to highlight Lamp. (menu 8-13)
2. Press ENTER to select.
The Lamp Menu will be displayed. (menu 8-14)
SERVICE
IDENTIFICATION
CHANGE PASSWORD
CHANGE PROJ. ADDRESS
CHANGE BAUDRATE PC
LAMP
MORE ...
Select with ↑ or ↓
then <ENTER>
<EXIT> to return
Menu 8-13
8.8.2

Constant Light Output (CLO)

What can be done?
Projectors in a multichannel setup may have different Lamp Runtimes, this will result in a difference in light output between the
projectors.
Within this menu it is possible to track and maintain the brightness levels of the projectors, the projectors will deliver a Constant Light
Output = CLO.
In a multichannel setup (max 14.) it is possible to link the CLO–values of all projectors, this is done by means of a master–slave
projector setup. One projector will act as master, all slave–projectors will track and maintain the CLO setting of this master–projector.
In a Linked CLO and/or Dynacolor™ setup a maximum of 14 projectors can be linked, all projectors must have
a different projector address between 0 and 13 and all projectors must have the same baudrate.
The CLO setting of one projector must be in the master position, all others must be in the slave position.
In a setup with one single projector, CLO will not work at all, when this projector is set in the slave position.
How to Connect the Master–Slave Projectors?
1. Connect a RS232 Terminator (Order number Z3498823) to the 'RS232 In' Input of the first projector in the chain.
2. Connect the RS232 Output of the first projector in the chain to the RS232 Input of the next projector.
3. Continue this daisy chain connection to connect all projectors in the set up.
How to Change the Constant Light Output Setting?
1. Push the cursor key ↑ or ↓ to highlight Constant Light Output. (menu 8-15)
2. Press ENTER to toggle CLO [On] or [Off].
LAMP
CONSTANT LIGHT OUTPUT [ON]
LINKED CLO [SLAVE]
MODE [ECONOMIC]
TARGET CLO LUMENS: 10000
_________________________________
Serial number :
003706
Article number :
R9840744
Run time :
140 hours
Remaining run time :
hours
Number of strikes :
Z-axis :
100 units
Select with ↑ or ↓
<ENTER> to toggle
<EXIT> to return
Menu 8-15
R5976781 TRACE+ 14/09/2004
LAMP
CONSTANT LIGHT OUTPUT [ON]
LINKED CLO [SLAVE]
MODE [ECONOMIC]
TARGET CLO LUMENS: 10000
_________________________________
Serial number :
Article number :
Run time :
Remaining run time :
hours
Number of strikes :
Z-axis :
100 units
Select with ↑ or ↓
<ENTER> to toggle
<EXIT> to return
Menu 8-14
860
160
003706
R9840744
140 hours
860
160
8. Service Mode
129

Advertisement

Table of Contents
loading

Table of Contents