2.154 Lamp Warning Runtime, Read

Description
Read the runtime when the warning menu, indicating the end of life of the lamp, first occurs. This warning menu is displayed on the
screen and is repeated every 30 minutes.
Command
Command [0]
Command [1]
Return Data
The return data-transfer being the lamp warning runtime in seconds consists of four data bytes. The first byte is the most significant
byte!
Formula: Lamp warning runtime (seconds) = Data[0] x 256³ + Data[1] x 256² + Data[2] x 256 + Data[3]
Example
Read the lamp warning runtime of a projector with address \x01. Suppose the message appears at 1000 hours.
Transmit
Start
Projector Address
Command [0]
Command [1]
Checksum
Stop
Receive (Acknowledge)
Start
Projector Address
Command [0]
Command [1]
Checksum
Stop
Receive (Answer)
Start
Projector Address
Command [0]
Command [0]
Data [0]
Data [1]
Data [2]
R5976538 BARCOREALITY SIM6 ULTRA SERIES 08/06/2005
\x76
\x8c
\xfe
\x01
\x76
\x8c
\x03
\xff
\xfe
\x01
\x00
\x06
\x07
\xff
\xfe
\x01
\x76
\x8c
\x00
\x36
\xee