2. RS232 Commands

2.15 Blanking Right, Read

Description
Read the actual value of the blanking right.
Command
Command [0]
Command [1]
Command [2]
Return Data
Data [0]
Data [1]
Example
Read the actual value of blanking right of a projector with address \x01. Suppose the blanking right equals 0.
Transmit
Start
Projector Address
Command [0]
Command [1]
Command [2]
Checksum
Stop
Receive (Acknowledge)
Start
Projector Address
Command [0]
Command [1]
Checksum
Stop
Receive (Answer)
Start
Projector Address
Command [0]
Command [1]
Command [2]
Data [0]
Checksum
Stop
36
\x21
\x4f
\x00
Blanking Right msb Value
Blanking Right lsb Value
\xfe
\x01
\x21
\x4f
\x00
\x71
\xff
\xfe
\x01
\x00
\x06
\x07
\xff
\xfe
\x01
\x21
\x4f
\x00
\x00
\x71
\xff