2.44 CLO Software Version, Read
Description
Read the CLO software version.
Availability
From software V1.22 (SIM6 ULTRA) and V1.00 (SIM6 ULTRA II).
Command
Command [0]
Command [1]
Command [2]
Return Data
Data [0]
The return data-transfer being the software version is a Pascal-Language String (see syntax).
Example
Read the CLO software version of a projector with address \x01. Suppose the CLO software version is V1.00.
Transmit
Start
Projector Address
Command [0]
Command [1]
Command [2]
Checksum
Stop
Receive (Acknowledge)
Start
Projector Address
Command [0]
Command [1]
Checksum
Stop
Receive (Answer)
Start
Projector Address
Command [0]
Command [1]
R5976538 BARCOREALITY SIM6 ULTRA SERIES 08/06/2005
\xfa
\xdb
\x17
Software Version
\xfe
\x01
\xfa
\xdb
\x17
\xed
\xff
\xfe
\x01
\x00
\x06
\x07
\xff
\xfe
\x01
\xfa
\xdb
2. RS232 Commands