2. RS232 Commands
2.122 Geometry Size Vertical, Read
Description
Read the vertical size value.
Availability
From software V2.02 (WARP6 MKII) and V1.01(SIM6 ULTRA HB)
Command
Command [0]
Command [1]
Data
Data [0]
Returned Data
Data [0]
Data [1]
Range is from -511 to +511 (2's complement).
Example
Suppose the value is 100 (=\x0064).
Transmit
Start
Projector Address
Command [0]
Command [1]
Data [0]
Checksum
Stop
Receive (Acknowledge)
Start
Projector Address
Command [0]
Command [1]
Checksum
Stop
Receive (Answer)
Start
Projector Address
168
\xfa
\xdb
\x4a
Geometry Size Vertical msb Value
Geometry Size Vertical lsb Value
\xfe
\x01
\xfa
\xdb
\x4a
\x20
\xff
\xfe
\x01
\x00
\x06
\x07
\xff
\xfe
\x01
R5976538 BARCOREALITY SIM6 ULTRA SERIES 08/06/2005