2.61 Contrast, Write

Description
Write a new contrast value.
Command
Command [0]
Command [1]
Data
Data [0]
Example
Set the contrast to \x30 on a projector with address \x01.
Transmit
Start
Projector Address
Command [0]
Command [1]
Data [0]
Checksum
Stop
Receive (Acknowledge)
Start
Projector Address
Command [0]
Command [1]
Checksum
Stop
R5976538 BARCOREALITY SIM6 ULTRA SERIES 08/06/2005
\x20
\x01
Contrast Value
\xfe
\x01
\x20
\x01
\x30
\x52
\xff
\xfe
\x01
\x00
\x06
\x07
\xff
2. RS232 Commands