2. RS232 Commands
2.252 Tint, Read
This command is only active when the internal decoder is used and the signal is NTSC.
Description
Read the actual tint value.
Command
Command [1]
Command [2]
Return Data
Data [0]
Example
Read the actual tint value of a projector with address \x01. Suppose the tint equals 0.
Transmit
Start
Projector Address
Command [0]
Command [1]
Checksum
Stop
Receive (Acknowledge)
Start
Projector Address
Command [0]
Command [1]
Checksum
Stop
Receive (Answer)
Start
Projector Address
Command [0]
Command [1]
Data [0]
Checksum
Stop
318
\x21
\x04
Tint Value
\xfe
\x01
\x21
\x04
\x26
\xff
\xfe
\x01
\x00
\x06
\x07
\xff
\xfe
\x01
\x21
\x04
\x00
\x26
\xff
R5976538 BARCOREALITY SIM6 ULTRA SERIES 08/06/2005