2. RS232 Commands

2.188 Period, Write

Description
Write the horizontal period in nanoseconds.
Command
Command [0]
Command [1]
Data
Data[0..3] = horizontal period in nanoseconds.
Data [0]
Data [1]
Data [2]
Data [3]
Example
Set the horizontal period to 48360 ns (xga_60) on a projector with address \x01.
Transmit
Start
Projector Address
Command [0]
Command [1]
Data [0]
Data [1]
Data [2]
Data [3]
Checksum
Stop
Receive (Acknowledge)
Start
Projector Address
Command [0]
Command [1]
Checksum
Stop
244
\x20
\x5b
MSB of value
LSB of value
\xfe
\x01
\x20
\x5b
\x00
\x00
\xbc
\xe8
\x20
\xff
\xfe
\x01
\x00
\x06
\x07
\xff