2. RS232 Commands
2.7
Blanking Bottom, Read
Description
Read the actual value of the blanking bottom.
Command
Command [0]
Command [1]
Command [2]
Return Data
Data [0]
Data [1]
Blanking Bottom = Data [0] x 256 + Data [1]
Example
Read the actual value of the blanking bottom of a projector with address \x01. Suppose the blanking bottom equals 0.
Transmit
Start
Projector Address
Command [0]
Command [1]
Command [2]
Checksum
Stop
Receive (Acknowledge)
Start
Projector Address
Command [0]
Command [1]
Checksum
Stop
Receive (Answer)
Start
Projector Address
Command [0]
Command [1]
Command [2]
26
\x21
\x4d
\x00
Blanking Bottom msb Value
Blanking Bottom lsb Value
\xfe
\x01
\x21
\x4d
\x00
\x6f
\xff
\xfe
\x01
\x00
\x06
\x07
\xff
\xfe
\x01
\x21
\x4d
\x00
R5976538 BARCOREALITY SIM6 ULTRA SERIES 08/06/2005