RGB3S/RG3SB Input - Separate Sync
RGB3S/RG3SB Input - Sync On Green
Component Input - Separate Sync
Component Input - Sync On Y
Component Input - Tri-Level Separate Sync
Component Input - Tri-Level Sync On Y
Data [1]
\x00
\x01
Example
Read the active source/slot number + mode of a projector with address \x01. Suppose the source number equals \x03 and its
mode equals \x01.
Transmit
Start
Projector Address
Command [0]
Checksum
Stop
Receive (Acknowledge)
Start
Projector Address
Command [0]
Command [1]
Checksum
Stop
Receive (Answer)
Start
Projector Address
Command [0]
Data [0]
Data [1]
Checksum
Stop
R5976538 BARCOREALITY SIM6 ULTRA SERIES 08/06/2005
Mode
\xfe
\x01
\x34
\x35
\xff
\xfe
\x01
\x00
\x06
\x07
\xff
\xfe
\x01
\x34
\x03
\x01
\x39
\xff
2. RS232 Commands