2. RS232 Commands

2.151 Lamp Runtime, Read

C
AUTION
Description
Read the lamp runtime in hours.
Command
Command [0]
Return Data
The return data-transfer being the lamp runtime in hours consists of ten data bytes.
Data [0] —[3]: Lamp Runtime in 200W modus (hours) = Data[0] x 256³ + Data[1] x 256² + Data[2] x 256 + Data[3]
Data [8] —[9]: Changed Lamp Modus Counter = Data[8] x 256 + Data[9]
Data [4] —[7]: Lamp Runtime in 250W modus (hours) = Data[4] x 256³ + Data[5] x 256² + Data[6] x 256 + Data[7]
Example
Read the lamp runtime of a projector with address \x01. Suppose the lamp runtime in 200W modus is 100 hours, the lamp runtime
in 250W modus is 50 hours, and the lamp modus has been switched 3 times.
Transmit
Start
Projector Address
Command [0]
Checksum
Stop
Receive (Acknowledge)
Start
Projector Address
Command [0]
Command [1]
Checksum
Stop
202
:
This command is only applicable on the SIM6 Ultra II series projectors.
\x64
\xfe
\x01
\x64
\x65
\xff
\xfe
\x01
\x00
\x06
\x07
\xff