2.243 Soft Edge Blanking, Write
Description
Write a Soft Edge Blanking value to a customfile.
Availability
From software V2.02 (WARP6 MKII) and V1.01(SIM6 ULTRA HB)
Command
Command [0]
Command [1]
Data
Data [0]
Data [1]
Data [2]
Data [3]
Data [4]
Data [5]
In case the WARPING OPTION is not active (= WARPLESS projector), position can only be 3 (="all").
Range is from 0 to 4999
Soft Edge Blanking Value = Data [2] x 256 + Data [3]
Value represents a percentage between 0 and 49,99%
306
\xfa
\xda
\x01
filenbr=number of the customfile (!! xxxxxxxx.g05 => filenbr
is 4 !!)
Location:
•
\x00 = Top
•
\x01 = Bottom
•
\x02 = Left
•
\x03 = Right
in case location = Top/Bottom
•
\x00 = Left
•
\x01 = Center
•
\x02 = Right
•
\x03 = All
in case location = Left/Right
•
\x00 = Top
•
\x01 = Center
•
\x02 = Bottom
•
\x03 = All
Soft Edge Blanking msb Value
Soft Edge Blanking lsb Value