A text box is displayed
Image 7-70
7.6.2
Lamp runtime warning
What can be done ?
When the lamp has reached a predetermined runtime , a warning message will be displayed on the screen. The lamp runtime
warning can be set in a range from 30 to 200 hours. The runtime warning is displayed by default at 30 hours before end of lamp
lifetime. This warning message can be removed by hitting Back on the RCU.
When the Warning messages are disabled in the hidden Service menu, the lamp runtime warning will only be
displayed at the next startup of the projector, not during a session. Enabling or disabling TextBox does not
affect the display of the lamp runtime warning.
How to set the lamp runtime warning ?
1. Press MENU to activate the Tool bar
2. Press → to select the Lamps item
3. Press ↓ to pull down the Lamps menu
4. Use ↑ or ↓ to select Runtime warning...
Image 7-71
5. Press ENTER
A dialog box is displayed
Image 7-72
6. Use ←or →, the numeric keys on the remote, or the keypad to change the runtime warning setting.
7.6.3
History
How to view the history ?
1. Press MENU to activate the Tool bar
2. Press → to select the Lamps item
R59770198 BARCO SIM 7D 13/02/2013
7. Advanced
91