Clamp Width, Write - Barco BarcoReality SIM6 Ultra R9040150 User Manual

Barcoreality sim6 ultra series/ serial communications basic
Hide thumbs Also See for BarcoReality SIM6 Ultra R9040150:
Table of Contents

Advertisement

2.32 Clamp Width, Write

Description
Write a new value for the clamp width.
Command
Command [0]
Command [1]
Data
Data [0]
Example
Set the clamp width to \x32 on a projector with address \x01.
Transmit
Start
Projector Address
Command [0]
Command [1]
Data [0]
Checksum
Stop
Receive (Acknowledge)
Start
Projector Address
Command [0]
Command [1]
Checksum
Stop
R5976538 BARCOREALITY SIM6 ULTRA SERIES 08/06/2005
\x20
\x68
Clamp Width Value
\xfe
\x01
\x20
\x68
\x32
\xbb
\xff
\xfe
\x01
\x00
\x06
\x07
\xff
2. RS232 Commands