D-Link xStack Reference Manual page 961

Dgs-3620 series layer 3 managed stackable gigabit switch
Hide thumbs Also See for xStack:
Table of Contents

Advertisement

xStack® DGS-3620 Series Layer 3 Managed Stackable Gigabit Switch CLI Reference Guide
Example
To configure the domain number of the PTP clock as 1 and assign a domain name of
internal_domain on the local unit, when the stacking mode is disabled:
DGS-3620-28SC:admin# config ptp clock domain_number 1 domain_name
internal_domain
Command: config ptp clock domain_number 1 domain_name internal_domain
Success.
DGS-3620-28SC:admin#
To configure the domain number of the PTP clock as 1 and assign a domain name of
internal_domain for the unit 1, when the stacking mode is enabled.
DGS-3620-28SC:admin#config ptp clock domain_number 1 unit 1 domain_name
internal_domain
Command: config ptp clock domain_number 1 unit 1 domain_name internal_domain
Success.
DGS-3620-28SC:admin#
83-6
config ptp boundary
Description
This command is used to configure the PTP boundary clock attributes and requires at least one
parameter to execute.
Format
config ptp boundary {priority1 <value 0-255> | priority2 <value 0-255>}(1)
Parameters
priority1 - (Optional) Specifies that the priority 1 attribute is used in the execution of the best
master clock algorithm. Lower values take precedence.
<value 0-255> - Enter the priority 1 value used here. This value must be between 0 and 255.
priority2 - (Optional) Specifies that the priority 2 attribute is used in the execution of the best
master clock algorithm. Lower values take precedence. In the event that the operation of the
BMC algorithm fails to order the clocks based on the values of priority1, the clock's class, and
the clock's accuracy; the priority2 attribute will allow the creation of lower values compared to
the other devices.
<value 0-255> - Enter the priority 2 value used here. This value must be between 0 and 255.
Restrictions
Only Administrator, Operator and Power-User level users can issue this command.
Example
To configure the priority1 value of the boundary clock as 127:
956