v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See Chapter 4, "Parts listing, System x3100 M4 Type 2582," on page 151 to determine which components
are customer replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a
trained service technician.
v Go to the IBM support website at http://www.ibm.com/supportportal/ to check for technical information,
hints, tips, and new device drivers or to submit a request for information.
Error code
Description
001800B
Microprocessors with mismatched cache size. 1. Make sure that the microprocessor is on the
001800C
Microprocessors with mismatched cache
type.
001800D
Microprocessors with mismatched cache
associativity.
001800E
Microprocessors with mismatched model.
Action
ServerProven website at http://www.ibm.com/
servers/eserver/serverproven/compat/us/.
2. Check the IBM support website for a firmware
update and update the server firmware to the
latest level (see "Updating the firmware" on page
267).
3. (Trained service technician only) Remove and
replace the affected microprocessor (error LED is
lit) with a supported type (see "Installing a
microprocessor and heat sink" on page 254).
1. Make sure that the microprocessor is on the
ServerProven website at http://www.ibm.com/
servers/eserver/serverproven/compat/us/.
2. Check the IBM support website for a firmware
update and update the server firmware to the
latest level (see "Updating the firmware" on page
267).
3. (Trained service technician only) Remove and
replace the affected microprocessor (error LED is
lit) with a supported type (see "Installing a
microprocessor and heat sink" on page 254).
1. Make sure that the microprocessor is on the
ServerProven website at http://www.ibm.com/
servers/eserver/serverproven/compat/us/.
2. Check the IBM support website for a firmware
update and update the server firmware to the
latest level (see "Updating the firmware" on page
267).
3. (Trained service technician only) Remove and
replace the affected microprocessor (error LED is
lit) with a supported type (see "Installing a
microprocessor and heat sink" on page 254).
1. Make sure that the microprocessor is on the
ServerProven website at http://www.ibm.com/
servers/eserver/serverproven/compat/us/.
2. Check the IBM support website for a firmware
update and update the server firmware to the
latest level (see "Updating the firmware" on page
267).
3. (Trained service technician only) Remove and
replace the affected microprocessor (error LED is
lit) with a supported type (see "Installing a
microprocessor and heat sink" on page 254).
29