Table 7. DSA Preboot messages (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved.
v See Chapter 4, "Parts listing, System x3100 M4 Type 2582," on page 151 to determine which components are customer
replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a Trained
service technician.
v Go to the IBM support website at http://www.ibm.com/supportportal/ to check for technical information, hints, tips, and
new device drivers or to submit a request for information.
Message
number
Component
405-902-xxx
Intel Ethernet
Device
405-903-xxx
Intel Ethernet
Device
Test
State
Test EEPROM
Failed
Test Internal
Failed
Memory
Description
Action
A failure was
1. Make sure that the component
detected while
firmware is at the latest level. The
testing non-volatile
installed firmware level is shown in
RAM.
the DSA event log in the
Firmware/VPD section for this
component. For more information, see
"Updating the firmware" on page 267.
2. Run the test again.
3. Replace the component that is
causing the error. If the error is
caused by an adapter, replace the
adapter. Check the PCI Information
and Network Settings information in
the DSA event log to determine the
physical location of the failing
component.
4. If the failure remains, go to the IBM
website for more troubleshooting
information at http://www.ibm.com/
systems/support/supportsite.wss/
docdisplay?brandind=5000008
&lndocid=SERV-CALL.
A failure was
1. Make sure that the component
detected while
firmware is at the latest level. The
testing internal
installed firmware level is shown in
memory.
the DSA event log in the
Firmware/VPD section for this
component. For more information, see
"Updating the firmware" on page 267.
2. Run the test again.
3. Check the interrupt assignments in
the PCI Hardware section of the DSA
event log. If the Ethernet device is
sharing interrupts, if possible, use the
Setup utility see "Using the Setup
utility" on page 271) to assign a
unique interrupt to the device.
4. Replace the component that is
causing the error. If the error is
caused by an adapter, replace the
adapter. Check the PCI Information
and Network Settings information in
the DSA event log to determine the
physical location of the failing
component.
5. If the failure remains, go to the IBM
website for more troubleshooting
information at http://www.ibm.com/
systems/support/supportsite.wss/
docdisplay?brandind=5000008
&lndocid=SERV-CALL.
139