IBM System x3100 M4 Type 2582 Problem Determination And Service Manual page 139

Type 2582
Hide thumbs Also See for System x3100 M4 Type 2582:
Table of Contents

Advertisement

Table 7. DSA Preboot messages (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved.
v See Chapter 4, "Parts listing, System x3100 M4 Type 2582," on page 151 to determine which components are customer
replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a Trained
service technician.
v Go to the IBM support website at http://www.ibm.com/supportportal/ to check for technical information, hints, tips, and
new device drivers or to submit a request for information.
Message
number
Component
166-821-xxx
IMM2
Test
State
IMM2 I2C Test
Aborted
Description
Action
IMM2 I2C test
1. Turn off the system and disconnect it
stopped: a
from the power source. You must
command response
disconnect the system from ac power
could not be
to reset the IMM2.
provided; IMM2
2. After 45 seconds, reconnect the
initialization is in
system to the power source and turn
progress.
on the system.
3. Run the test again.
4. Make sure that the DSA code is at
the latest level. For more information
and to download the utilities, go to
http://www.ibm.com/systems/support/
supportsite.wss/
docdisplay?brandind=5000008
&lndocid=SERV-DSA.
5. Make sure that the IMM2 firmware is
at the latest level. The installed
firmware level is shown in the DSA
event log in the Firmware/VPD
section for this component. For more
information, see "Updating the
firmware" on page 267.
6. Run the test again.
7. If the failure remains, go to the IBM
website for more troubleshooting
information at http://www.ibm.com/
systems/support/supportsite.wss/
docdisplay?brandind=5000008
&lndocid=SERV-CALL.
119
Chapter 3. Diagnostics

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents