IBM System x3100 M4 Type 2582 Problem Determination And Service Manual page 80

Type 2582
Hide thumbs Also See for System x3100 M4 Type 2582:
Table of Contents

Advertisement

Table 6. IMM2 error messages (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v If an action step is preceded by "(Trained technician only)," that step must be performed only by a trained
technician.
806f0323-2101xxxx Power cycle of system
initiated by IPMI
Watchdog.
806f0823-2101xxxx Watchdog Timer
interrupt occurred for
IPMI Watchdog.
806f0109-1301xxxx Host power has been
power cycled.
806f0009-1301xxxx Host Power has been
turned off.
80030012-2301xxxx Sensor OS RealTime
Mod has deasserted.
80030006-2101xxxx Sensor Sig Verify Fail
has deasserted.
80070202-0701xxxx Sensor Planar Fault
has transitioned to
critical from a less
severe state.
806f0013-1701xxxx A front panel NMI has
occurred on system
%1.
(%1 =
CIM_ComputerSystem.
ElementName)
60
IBM System x3100 M4 Type 2582: Problem Determination and Service Guide
Info
A power cycle by
watchdog has
been detected.
Info
A watchdog timer
interrupt has been
detected.
Info
A power unit that
has been power
cycled has been
detected.
Info
A power unit has
been disabled.
Info
An implementation
has detected a
sensor has
deasserted.
Info
An implementation
has detected a
sensor has
deasserted.
Error
A sensor has
changed to Critical
state from a less
severe state.
Error
An operator
information panel
NMI/diagnostic
interrupt has
occurred.
No action; information only.
No action; information only.
No action; information only.
No action; information only.
No action; information only.
No action; information only.
1. Check the system-event log.
2. Check for an error LED on the
system board.
3. Replace any failing device.
4. Check for a server firmware
update.
Important: Some cluster solutions
require specific code levels or
coordinated code updates. If the
device is part of a cluster solution,
verify that the latest level of code
is supported for the cluster solution
before you update the code.
5. (Trained technician only) Replace
the system board ("Removing the
system board" on page 258 and
"Installing the system board" on
page 261).
1. Check the device driver.
2. Reinstall the device driver.
3. Update all device drivers to the
latest level.
4. Update the firmware (UEFI and
IMM2) (see "Updating the
firmware" on page 267).

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents