Table 6. IMM2 error messages (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v If an action step is preceded by "(Trained technician only)," that step must be performed only by a trained
technician.
40000025-
The Chassis Event Log
00000000
(CEL) on system %1 is
75% full.
(%1 =
CIM_ComputerSystem.
ElementName)
40000026-
The Chassis Event Log
00000000
(CEL) on system %1 is
100% full.
(%1 =
CIM_ComputerSystem.
ElementName)
40000027-
%1 Platform Watchdog
00000000
Timer expired for %2.
(%1 = OS Watchdog or
Loader Watchdog; %2 =
OS Watchdog or
Loader Watchdog)
40000028-
IMM Test Alert
00000000
Generated by %1.
(%1 = user ID)
40000029-
Security: Userid: '%1'
00000000
had %2 login failures
from an SSH client at
IP address %3.
(%1 = user ID; %2 =
MaximumSuccessive
LoginFailures (currently
set to 5 in the
firmware); %3 = IP
address,
xxx.xxx.xxx.xxx)
40000030-
IPv6 disabled by user
00000000
[arg1].
40000031-
IPv6 static IP
00000000
configuration enabled
by user [arg1].
40000032-
IPv6 DHCP enabled by
00000000
user [arg1].
70
IBM System x3100 M4 Type 2582: Problem Determination and Service Guide
Info
The IMM event log
is 75% full. When
the log is full, older
log entries are
replaced by newer
ones.
Info
The IMM event log
is full. When the
log is full, older log
entries are
replaced by newer
ones.
Error
A Platform
Watchdog Timer
Expired event has
occurred.
Info
A user has
generated a test
alert from the IMM.
Error
A user has
exceeded the
maximum number
of unsuccessful
login attempts from
SSH and has been
prevented from
logging in for the
lockout period.
Info
IPv6 protocol is
disabled by user.
Info
IPv6 static address
assignment
method is enabled
by user.
Info
IPv6 DHCP
assignment
method is enabled
by user.
To avoid losing older log entries, save
the log as a text file and clear the log.
To avoid losing older log entries, save
the log as a text file and clear the log.
1. Reconfigure the watchdog timer to
a higher value.
2. Make sure that the IMM Ethernet
over USB interface is enabled.
3. Reinstall the RNDIS or cdc_ether
device driver for the operating
system.
4. Disable the watchdog.
5. Check the integrity of the installed
operating system.
No action; information only.
1. Make sure that the correct login ID
and password are being used.
2. Have the system administrator
reset the login ID or password.
No action; information only.
No action; information only.
No action; information only.
Need help?