IBM System x3100 M4 Type 2582 Problem Determination And Service Manual page 75

Type 2582
Hide thumbs Also See for System x3100 M4 Type 2582:
Table of Contents

Advertisement

Table 6. IMM2 error messages (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v If an action step is preceded by "(Trained technician only)," that step must be performed only by a trained
technician.
806f050d-0400xxxx
Array %1 is in critical
806f050d-0401xxxx
condition.(%1 =
806f050d-0402xxxx
CIM_ComputerSystem.
806f050d-0403xxxx
ElementName)
806f050d-0404xxxx
806f050d-0405xxxx
806f050d-0406xxxx
806f050d-0407xxxx
806f060d-0400xxxx
Array %1 has failed.
806f060d-0401xxxx
(%1 =
806f060d-0402xxxx
CIM_ComputerSystem.
806f060d-0403xxxx
ElementName)
806f060d-0404xxxx
806f060d-0405xxxx
806f060d-0406xxxx
806f060d-0407xxxx
806f070d-0400xxxx
The Drive n Status
806f070d-0401xxxx
rebuilt has been in
806f070d-0402xxxx
progress. (n = hard disk
806f070d-0403xxxx
drive number)
806f070d-0404xxxx
806f070d-0405xxxx
806f070d-0406xxxx
806f070d-0407xxxx
PCI messages
806f0021-3001xxxx PCI fault has been
detected for PCI n.
(n = PCI slot number)
Error
An array is in a
critical state.
(Sensor = Drive n
Status) (n = hard
disk drive number)
Error
An array is in a
failed state.
(Sensor = Drive n
Status) (n = hard
disk drive number)
Info
The Drive n has
rebuilt in progress.
(n = hard disk
drive number)
Error
A PCI fault has
been detected.
1. Make sure that the RAID adapter
firmware and hard disk drive
firmware is at the latest level.
2. Make sure that the SAS cable is
connected correctly.
3. Replace the SAS cable.
4. Replace the RAID adapter.
5. Replace the hard disk drive that is
indicated by a lit status LED.
1. Make sure that the RAID adapter
firmware and hard disk drive
firmware is at the latest level.
2. Make sure that the SAS cable is
connected correctly.
3. Replace the SAS cable.
4. Replace the RAID adapter.
5. Replace the hard disk drive that is
indicated by a lit status LED.
No action; information only.
1. Check the PCI LED.
2. Reseat the affected adapters and
riser card.
3. Update the server firmware (UEFI
and IMM2) and adapter firmware.
Important: Some cluster solutions
require specific code levels or
coordinated code updates. If the
device is part of a cluster solution,
verify that the latest level of code
is supported for the cluster solution
before you update the code.
4. Remove both adapters.
5. Replace the riser cards.
6. (Trained technicians only) Replace
the system board (see "Removing
the system board" on page 258
and "Installing the system board"
on page 261).
Chapter 3. Diagnostics
55

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents