Time Protocols
TimeP: Viewing, Selecting, and Configuring
Table 8-2.Timep Parameters
SNTP Parameter Operation
Time Sync
Used to select either TIMEP (the default), SNTP, or None as the time synchronization method.
Method
Timep Mode
Disabled
The Default. Timep does not operate, even if specified by the Menu interface Time Sync Method
parameter or the CLI timesync command.
DHCP
When Timep is selected as the time synchronization method, the switch attempts to acquire a Timep
server IP address via DHCP. If the switch receives a server address, it polls the server for updates
according to the Timep poll interval. If the switch does not receive a Timep server IP address, it cannot
perform time synchronization updates.
Manual
When Timep is selected as the time synchronization method, the switch attempts to poll the specified
server for updates according to the Timep poll interval. If the switch fails to receive updates from the
server, time synchronization updates do not occur.
Server
Used only when the TimeP Mode is set to Manual. Specifies the IP address of the TimeP server that
Address
the switch accesses for time synchronization updates. You can configure one server.
Poll Interval
Default: 720 minutes. Specifies the interval the switch waits between attempts to poll the TimeP server
for updates.
(minutes)