Figure 43 Firmware tab
4.
On the Firmware tab, select the box next to each component to be upgraded.
5.
Click Apply Updates. The status reports that an upgrade is in progress.
CAUTION:
power cycle one controller and then upgrade and power cycle the other controller. Otherwise,
the firmware may synchronize with the controller running the previous version of code.
If, after upgrading the firmware on the controllers, the storage system does not see any storage
or the controllers do not start, see
(page
59).
NOTE:
multiple components, such as hard drives, the upgrade takes more time.
6.
Reboot the server blade from the Start menu, if needed.
A message appears on the Firmware tab to alert you if a reboot is required after each
component firmware upgrade. After the upgrade completes, the Firmware Status changes
from "Firmware updates recommended" to "A reboot is required."
NOTE:
checkmark displays next to the component name.
7.
Open the Firmware tab in the System Manager and verify that the upgrade was successful.
You can also check the upgrade status on the System Summary tab.
If the firmware upgrade failed, the component is listed as an available upgrade in the Firmware
tab after the firmware upgrade and reboot. To determine the next steps for a successful firmware
upgrade, go to the Reports tab (see
58
Upgrading the storage system
When upgrading the controller firmware, you must complete the upgrade and
Each firmware upgrade takes a few minutes to complete. If you are upgrading
If a reboot is not required after the component firmware upgrade completes, a green
"Resolving errors after the HP 1210m controller upgrade"
"Reports" (page
33)) and run a report.