HP X5000 G2 Administrator's Manual page 35

Hp network storage system
Table of Contents

Advertisement

Table 2 Server blade LEDs status (continued)
Item
Description
3
NIC 1 LED*
4
Flex- 1 0 NIC 2 LED*
5
Reserved
6
System power LED
*Actual NIC numbers depend on several factors, including the operating system installed on the server blade.
Figure 25 Front LED display board
Table 3 Front LED status
Item
Description
1
Hard drive LEDs
Normal mode (UID LED is
solid)
Status
Amber = Degraded condition
Red = Critical condition
Green = Network linked
Green flashing = Network activity
OFF = No link or activity
Green = Network linked
Green flashing = Network activity
OFF = No link or activity
Green = On
Amber = Standby (auxiliary power available)
OFF = OFF
Status
Green = The drive is online, but is not currently active.
Flashing irregularly green = The drive is online and it is operating normally.
Flashing green (1 Hz) = Do not remove the drive. Removing the drive may
terminate the current operation and cause data loss. The drive is rebuilding,
or it is part of an array that is undergoing expansion, logical drive extension,
a stripe size migration, or RAID migration.
Flashing amber/green = Drive is configured and indicating a predictive
failure. The drive may also be undergoing a rebuild, expansion, extension,
or migration.
Flashing amber (1 Hz) = A predictive failure alert has been received for
this drive. Replace the drive as soon as possible.
Amber = Drive failure, link failure, or mismatched configuration.
OFF = The drive is offline, a spare, or not configured as part of an array.
Component LEDs
35