Table 13 Known issues (continued)
Issue
When creating a volume for a new pool,
if there is no redundancy and the volume
is in a Bad state, the Create a Volume
wizard will fail at the format and
partition step. The following error
message will display:
Failed to located LUN on host
When configuring iLO settings in the
Initial Configuration Tasks window,
changing iLO settings on the second
node may result in an error that the user
has insufficient permissions. This can
happen even if the user is a domain
administrator and belongs to the
administrator group on each node. The
User Access Control system prevents the
application from running on the second
node. No prompt is displayed to the user
to allow execution on the second node.
You have installed the System Recovery
image on a storage system that has an
external disk enclosure connected to the
storage system and the disk enclosure
either has existing LUNs or a degraded
disk. After installing the image, the
Hardware Status tab in the System
Manager and the System Management
Homepage indicate the disk drives are
degraded and, if you use the Create a
Volume wizard, the disk drives are only
displayed for one node.
If you connect the storage system to more
than one network or subnet and then run
the Create a File Server wizard, the
wizard may fail with the following error: the IP address, network mask, and gateway is applicable. You can also
Static network xx.xx.xx.x /xx
was not configured. Please
use -StaticAddress to use
this network or use
-IgnoreNetwork to use it.
46
Monitoring and troubleshooting the storage system
Resolution
controller 1: 500143800442E600
Manufacturer: HP
Model: 1210m
Part Number: 607190-001
SKU: None
Serial Number: PBGJR0XTAZ407Z
Firmware Version: 0156
Firmware Build: 2011061702
Peer Controller: 500143800442D690
Operational Status: Degraded, Cache flash backup
hardware failure, Cache disabled: low battery charge
Health Status: Degraded/Warning
Cache Size: 1073741824
Read Cache Default: Enabled
Write Cache Default: Enabled
Battery 0 Status: charging
Battery 0 Estimated Charge Remaining: 0%
Delete the volume that is in a Bad state and try again to create a volume.
Log on to the second node using the local administrator account and
configure the iLO settings using the iLO Configuration Utility in the HP
System Tools program group.
Connect to iLO and change the settings using the iLO user interface.
NOTE:
Changing the iLO network settings may cause your iLO sessions to
disconnect.
Delete existing LUNs using either the Delete a Volume or Create a Witness
Disk wizard after installing the System Recovery image.
This error message typically appears when the subnet mask is incorrectly
specified for one or more network adapters. Verify that each network adapter
is correctly configured to operate on the respective network by checking that
execute the ping command to confirm connectivity on the network.