HORIZONTAL TERMINATIONS (top vent)
NOTE: Horizontal sections re-
quire 1/4" (6 mm) rise for every
12" (305 mm) of travel.
IMPORTANT: If top venting, follow
instructions on pages 19-20 to convert
fireplace from rear vent ready to top
.
vent ready
NOTE: Flange on top stand-off
must be bend upwards to a 90˚
angle when top venting.
CAUTION: This gas appliance
must not be connected to or
joined with any other chimney
flue serving another appliance.
90° ELBOW
VENTING
90° ELBOW
(4.27 m)*
NOTE: Page 26 has information on restrictor installation in conjunction with
venting installation. Page 51 has information on restrictor recommendations
depending on burner flame appearance and instructions on installation after
venting is completed.
PAGE 22
(Horizontal)
MINIMUM HORIZONTAL
VENTING (top vent)
6" (152 mm) VENT
PIPE SECTION
MAXIMUM HORIZONTAL VENTING
14 ft.*
TERMINATION CAP
(top venting)
TERMINATION CAP