kozy heat Thief River Falls-TRF 56701 Installation And Operation Manual page 47

Direct vent fireplace
Hide thumbs Also See for Thief River Falls-TRF 56701:
Table of Contents

Advertisement

56701-RF LIGHTING AND SHUTDOWN (cont.)
INITIAL USE OF TRANSMITTER
1.
Turn gas control knob to the PILOT
position. Move LOCAL / REMOTE
switch to the LOCAL position for at
least two (2) seconds, then move
switch to the REMOTE position.
2.
Press FAN or FLAME button on the
transmitter within thirty (30) seconds
of the switch change.
3.
Turn gas control knob to the ON position.
The LED will blink, indicating that the transmitter will now work with the receiver / valve. If the switch stays in
the REMOTE position, the TR8220A Transmitter will control the main valve, flame modulation level and fan
control.
If the LOCAL / REMOTE switch is in the LOCAL position, the receiver / valve will be at the highest setting.
TURN THE BURNER OFF
LOCAL SETTING: Turn control knob clockwise to the PILOT position.
REMOTE SETTING: The TR8220A transmitter can shut off the main burner and fan. However,
the control is still „ON‟ and a command from the transmitter can turn on the main burner and fan.
TURN THE SYSTEM OFF
1.
Open lower grill to access the gas valve & controls.
2.
Turn gas control knob clockwise to the OFF position. This closes the main gas and safety valves.
The transmitter cannot turn on the main burner or the fan.
NOTE: If the manual switch is in the LOCAL position,
the main burner will turn on immediately.
NOTE: This control valve has an interlock device. If
pilot has been turned off, it cannot be relit until the
thermocouple has cooled, (approximately 60 seconds).
1.
WITHIN
30 SECONDS
PRESS
2.
3.
PAGE 46
IMPORTANT:
On the initial use of the transmitter, a recognition operation is
required between the receiver / valve and the transmitter.
2 SECONDS
OR

Advertisement

Table of Contents
loading

This manual is also suitable for:

Thief river falls-trf 56701-rf

Table of Contents