56701-RF REMOTE RECEIVER FUNCTIONS

IMPORTANT: PLEASE REVIEW AND RETAIN THE INSTRUCTIONS INCLUDED WITH THE RF TRANSMITTER. IT PRO-
VIDES ADDITIONAL INFORMATION AND DETAILS CONCERNING THE OPERATIONAL PROCEDURES AND FUNCTIONS
FOR THE RF REMOTE CONTROL.
FUNCTIONS:
Flame powered system.
Flame powered flame modulation.
Electronics integrated into valve to provide thermostat, flame, and fan functions with RF commands.
Temperature compensated RF receiver.
Main burner runs on „HIGH‟ when manual switch is set to „LOCAL‟.
TRANSMITTER SIGNAL:
When transmitter is in Auto mode, a signal is sent every 10 minutes if there is a change in room temperature.
When transmitter is in „ON‟ or „OFF‟ modes, a signal is sent every 10 minutes with the „ON‟ or „OFF‟ status condition.
Make sure antennae is not touching metal.
RECEIVER SHUTDOWN OF BURNER:
In the remote „AUTO‟ mode, the valve shuts off if it does not receive a signal within 3 hours from the transmitter.
In the „LOCAL‟ mode, the valve does not shut off.
In the remote „MANUAL‟ mode, the valve shuts off if it does not receive a signal within 6 hours from the transmitter.
THERMOPILES:
The negative leads (white) must be connected to the terminals marked with white dots.
LED TROUBLESHOOTING:
In normal operation, LED blinks once every two seconds; also, LED will be on for one second after every valid command received by
the RV83110D; these are not error codes.
Failure codes (see table) can occur anytime after the pilot burner is lit. Failure code timing is 1/4 second on, 1/2 second off.
Sequence is failure code followed by LED not blinking for four seconds.
In the event of multiple failure codes, the next failure code follows the previous code failure by approximately three seconds.
Code
Service Action
8
Replace valve
7
Confirm stepper motor connection exists
4
Fuel conversion plug missing or has poor
connection (RV8310E only)
3
Replace thermopile with Q313
2
Device too hot. Check application
1
None required. This is normal operation
and indicates the control is powered
MODE:
AUTO
ON
OFF
COUNTDOWN
TIMER
PAGE 48
RT8220A TRANSMITTER
FAN
DISPLAY:
Room Temperature
Set Temperature
Flame Height Level
Fan Speed Level
Countdown Timer
Low Battery
FLAME
UP:
Increases Flame height,
Fan Speed, Timer, or Set
Point
DOWN:
Decrease Flame Height,
Fan Speed, Timer, or Set
Point