Gas Line Connection - kozy heat Thief River Falls-TRF 56701 Installation And Operation Manual

Direct vent fireplace
Hide thumbs Also See for Thief River Falls-TRF 56701:
Table of Contents

Advertisement

GAS CONVERSION
This fireplace is manufactured for use with Natural Gas. An LP conversion kit, is included with this fireplace. Follow instructions included with
the conversion kit if converting to LP gas.
Model 56701; #OCK-H38N
Model 56701-RF; #OCK-H625L-RF
ATTENTION: The conversion shall be carried out in accordance
with the requirements of the provincial authorities having jurisdic-
tion and in accordance with the requirements of the ANSI Z223.1
installation code.
NOTE: This fireplace is equipped with a 3/8"(10 mm) x 18" (457
mm) long flexible gas connector and manual shut-off valve. The
gas line should be run to the point of connection where the shut-off
valve and flexible gas line will connect.
NOTE: A listed (and Commonwealth of Massachusetts approved)
12" (13 mm) T- handle manual shut-off valve and flexible gas con-
nector (included) are connected to the 1/2" (13 mm) control valve
inlet.
MINIMUM INLET GAS PRESSURE
MAXIMUM INLET GAS PRESSURE
MANIFOLD PRESSURE (HI)
MANIFOLD PRESSURE (LO)
ORIFICE SIZE
INPUT BTU/hr.
MINIMUM INPUT BTU/hr.
EFFICIENCY
AFUE
P-4 AFE
NOTE: The appliance and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing
of that system at pressures in excess of ½ psi.
NOTE: The appliance must be isolated from the gas supply piping system by closing its individual manual shut-off valve during any pres-
sure testing of the gas line at test pressures equal to or less than ½ psi (3.5 kPa).
NOTE: For high altitude installations, consult the local gas distributor or the authority having jurisdiction for proper rating methods.
IMPORTANT: The efficiency rating of this appliance is a product of thermal efficiency rating determined under continuous operating condi-
tions and was determined independently of any installed system.

GAS LINE CONNECTION

56701
NATURAL GAS
5.0 inches W.C.
(7.0 W.C. recommended)
10.5 inches W.C.
3.5 inches W.C
1.7 inches W.C.
#38
28,000
20,000
71.90%
70.73
66.89
PAGE 17
CAUTION: Installation of the gas line must only be
done by a qualified person in accordance with local
building codes, if any.If not, follow ANSI 223.1.
Commonwealth of Massachusetts:
Installation must be done by a licensed plumber of gas fitter.
LP GAS
NATURAL GAS
11.0 inches W.C.
5.0 inches W.C.
(recommended)
(7.0 W.C. recommended)
13.0 inches W.C.
10.5 inches W.C.
10.0 inches W.C.
3.5 inches W.C
6.3 inches W.C
1.7 inches W.C.
#.0625
#38
28,000
28,000
21,000
20,000
74%
71.90%
73.29%
70.73
67.64
66.89
56701-RF
LP GAS
11.0 inches W.C.
(recommended)
13.0 inches W.C.
10.0 inches W.C.
6.3 inches W.C
#.0625
28,000
21,000
74%
73.29%
67.64

Advertisement

Table of Contents
loading