VERTICAL TERMINATIONS
MINIMUM VERTICAL VENTING
(rear vent)
CAUTION: This gas appliance must not
be connected to or joined with any other
chimney flue serving another appliance.
NOTE: Flange on top stand-off must
be bend upwards to a 90˚ angle when
top venting.

RESTRICTOR INSTALLATION

TO BE USED AT INSTALLER DISCRETION.
Large Restrictor
NOTE: Page 51 has information on restrictor recommendations depending
on burner flame appearance and instructions on installation after venting is
completed.
MAXIMUM VERTICAL VENTING
TERMINATION CAP
14"
(356 mm)
90° ELBOW
Remove tab (s) to create
small restrictor
VENTING
(Vertical)
(rear vent)
22 ft.
(7.71 m)
Bend tabs to approx. 80 degree
angles to create tension to hold
itself in place when installed.
PAGE 26
MAXIMUM VERTICAL VENTING
(top vent)
TERMINATION CAP
Slide restrictor into exhaust pipe on top of fireplace with
tabs pointing towards you prior to attaching venting.
33 ft.
(10.06 m)