RF REMOTE TROUBLESHOOTING (56701-RF only)
AUTO PATH
If the manual switch is set to
REMOTE, press the Mode
button to display AUTO on
the transmitter, Does the
transmitter display the room
and temperature setting?
Yes
If the setting is above room
temperature on the transmit-
ter, does the main valve and
fan turn on?
Yes
If the setting is below room
temperature on the transmit-
ter, does the main valve and
fan turn off?
Yes
Turn pilotstat knob to OFF to
turn valve completely off
Yes
Set manual switch to
LOCAL or REMOTE
Yes
Light pilot burner
Yes
Did the LED stop
Yes
blinking?
Yes
Release pilotstat
knob
Yes
Turn pilotstat knob
from PILOT to ON
Yes
Cycle switch once and leave
in remote. Press any key on
transmitter for recognition
operation
Move switch from LOCAL to
REMOTE. Press any key
within 30 seconds.
No
No
Five minute wait
period
Review LED failure
analysis
Choose LOCAL or REMOTE
Yes
path. Set switch to LOCAL or
REMOTE
REMOTE PATH
If the manual switch is set to
REMOTE, set the Mode
button to display "ON". Does
the transmitter control the
main burner and fan ?
Yes
Does transmitter change
levels of flame height, fan
speed and set temperature?
Yes
Set levels of flame height and
fan to "0" to shut off main
burner and fan
Turn pilotstat knob to OFF to
turn valve completely off
If the manual switch is set to
LOCAL, did the main burner
light?
Yes
Does the transmitter control
fan
Yes
Turn pilotstat knob to PILOT
to turn off main burner
Turn pilotstat knob to OFF to
turn valve completely off
PAGE 56
Move switch from
MANUAL to RE-
MOTE. Press any key
on transmitter.
No
LOCAL PATH
Move switch from
LOCAL to REMOTE.
Press any key on trans-
mitter. Move switch
back to LOCAL.
No