STAND-OFF
FIREPLACE FRONT
LEFT SIDE
GAS LINE HOLE
5-1/2"
(140 mm)
2-1/8"
(54 mm)
3-3/8"
(86 mm)
CLEARANCES
Top of unit face to framing - 3-1/2" (89 mm)
From unit left & right sides & back - 1/2" (13 mm)
To flooring - 0" (0 mm)
Unit top to ceiling - 31" (787 mm)
Unit side to adjacent sidewall - 0" (0 mm)
Unit front to combustibles - 36" (914 mm)
Top of unit to 3/4" (19 mm) trim - 6" (152 mm)
Mantel must be a minimum of 8" (203 mm) above top of
unit. The maximum mantel depth at this height is 8" (203
mm) deep. See additional mantel clearance configurations
on page 13 of this installation manual.
SPECIFICATIONS
WARNING:
NON-COMBUSTIBLE ZONE:
STAND-OFFS PROVIDE THE 3-1/2" (89 mm)
MINIMUM CLEARANCE TO HEADER. USE
ONLY NON-COMBUSTIBLE MATERIAL IN
THIS AREA FOR THE ENTIRE WIDTH OF
FIREPLACE. DO NOT USE WOOD, SHEET-
ROCK ETC. IN THIS ZONE.
NOTE: OTHER CLEARANCES APPLY.
ALL CLEARANCES MUST BE MAIN-
TAINED. REFER TO PAGE 13 FOR
MORE INFORMATION.
THERMOSTAT WIRE
PAGE 7
FIREPLACE FRONT
RIGHT SIDE
GAS LINE HOLE
ELECTRICAL
ACCESS
5-3/4"
(146 mm)
9-1/4"
(235 mm)
WARNING: TOP STAND-OFF BRACKET MUST BE
ATTACHED TO FIREPLACE. DO NOT REMOVE.
CAUTION: STAND-OFF BRACKETS ARE NOT
LOAD BEARING.
STAND-OFF