Components List; Installation Overview; Placement Clearance Requirements - kozy heat Thief River Falls-TRF 56701 Installation And Operation Manual

Direct vent fireplace
Hide thumbs Also See for Thief River Falls-TRF 56701:
Table of Contents

Advertisement

MODEL #56701 COMPONENTS LIST
(#TRF-770) - Millivolt Board Assembly with 18" Flexible Gas
Line attached
(#700-203) - Manual Gas Shut-off Valve
(#TRF-030A) - Burner Cover
(#TRF-035) - Burner Tube
(#TRF-500A) - Log Package
(#TRF-057T) - Glass Frame Assembly
(#OCK-S53A) - LP Conversion Kit
(#600-083) - Receptacle / Speed Control Assembly with (3)
Wire Nuts
(#900085) - 4" Restrictor Plate
(#500-TRF) - Grill Assembly: Upper Hood, Upper Louver,
Lower Grill

INSTALLATION OVERVIEW

1.
Frame an opening for the fireplace, allowing for vent installation (top or rear) and type of installation (corner or flat wall application).
2.
If masonry (optional) will be used, prepare foundation for the masonry load. A lintel is required to support the added weight above the
fireplace.
3.
Attach nailing flanges to fireplace.
4.
Insert fireplace into framing.
5.
Install the hearth (if applicable).
6.
Complete the gas line installation.
7.
Complete the electrical hook-up. Install any standard or optional electrical components at this time.
8.
Complete the venting installation.
9.
Secure fireplace to flooring through holes located in the outer box bottom and to framing with nailing flanges. Verify all clearances at
this point.
10. Install facing material, mantel or cabinetry, allowing room for optional full face doors, if applicable.
11. Install logs.
12. Install grills and optional decorative doors / faces.
13. Verify proper operation of fireplace and all components.

PLACEMENT CLEARANCE REQUIREMENTS

This fireplace must be installed on a level surface capable of supporting the fireplace and venting.
Fireplace must be placed directly on wood or non-combustible surface (not linoleum or carpet) extending the entire depth and width of
fireplace.
Due to high surface temperatures, fireplace should be located out of traffic and away from furniture and draperies.
This fireplace may be installed in a bedroom.
Please be aware of the large amount of heat this fireplace will produce when determining a location.
SPECIFICATIONS
MODEL #56701-RF COMPONENTS LIST
(#TRF-800-RF) - Millivolt Board Assembly with 18" Flexible
Gas Line attached
(#700-203) - Manual Gas Shut-off Valve
(#TRF-030A) - Burner Cover
(#TRF-035) - Burner Tube
(#TRF-G900) - Refractory Set
(#TRF-500A) - Log Package
(#PRC-028-RF - RF Fan Kit
(#TRF-057T) - Glass Frame Assembly
(#OCK-H625L-RF) - LP Conversion Kit
(#700-108) - Remote control
(#900085) - 4" Restrictor Plate
(#500-TRF) - Grill Assembly: Upper Hood, Upper Louver,
Lower Grill
PAGE 8
NOTE: The qualified installer should follow the
procedure best suited for the installation.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Thief river falls-trf 56701-rf

Table of Contents