Determine the exact position of your fireplace, including hearth height, width, and depth, (if applicable). If possible, place fireplace in such a
manner that the vent termination will be placed between two studs, eliminating the need for additional framing.
If masonry is to be used (optional), prepare the necessary foundation for the masonry load. When masonry construction is being used, a lintel
must be used over the top of fireplace to support the added weight.
Build hearth to desired size and height. If a hearth extension is desired, combustible material may be used.
NOTE: Consider height of hearth
finish material (stone, brick, etc.) when building
fireplace platform. The bottom of the fireplace
must be level with finished hearth to allow for
lower grill operation and proper fit of optional
decorative full door faces.
IMPORTANT: Vent cap location must be in compli-
ance with the guidelines on page #31 of this manual.

VERTICAL TERMINATIONS

Follow vent pipe manufacturer‟s installation instructions for vertical
terminations. A minimum 1" (25 mm) clearance on all sides of vertical
vent pipe must be maintained.

HORIZONTAL TERMINATIONS

Follow vent pipe manufacturer‟s installation instructions for horizontal
terminations. Include the required 1-1/2" (38 mm) top clearance and
1" (25 mm) sides and bottom clearances for approved rigid vent systems
and the Kozy Heat #700 series flexible vent system.
MINIMUM HORIZONTAL FRAMING DIMENSIONS
(REAR VENT APPLICATIONS)
VENT PIPE TOP (A)
RIGID PIPE
31" (787 mm)
MINIMUM HORIZONTAL FRAMING DIMENSIONS
(TOP VENT APPLICATIONS)
VENT PIPE TOP (A)
RIGID PIPE
44-1/8" (1121 mm)
FLEX PIPE
52-1/2" (1333 mm)
MINIMUM HORIZONTAL FRAMING DIMENSIONS
(CORNER INSTALLATIONS)
VENT PIPE TOP (A)
RIGID PIPE
44-1/8" (1121 mm)
CAUTION: Due to high temperatures, this fireplace should be located out
of traffic areas and away from furniture and draperies.
FRAMING
FRAMED OPENING TOP (B)
32-1/2" (826 mm)
FRAMED OPENING TOP (B)
45-5/8" (1159 mm)
53-1/2 (1359 mm)
FRAMED OPENING TOP (B)
45-5/8" (1159 mm)
PAGE 11
WARNING: Install fireplace on hard metal or wood surface
extending the full width and depth of fireplace. Minimum plat-
form size: 40-3/4" (1035 mm) wide x 15-3/4" (400mm) deep.
FIRE HAZARD: Do NOT install directly on carpeting, vinyl, or
any combustible material other than wood.
CAUTION: Cold air transfer area. The sur-
rounding fireplace chase must comply with all
clearances as outlined in this manual and be
constructed in compliance with local building
codes. Outside walls should be insulated to pre-
vent cold air from entering room.