CAUTION: If the burner and/or pilot have been burning, use the ap-
propriate protection to avoid burns or damage to personal property
before removing any components.
1.
Turn gas control knob to the „OFF‟ position.
2.
Shut off gas supply at the manual shut-off valve.
3.
Disconnect gas line flex tube from the manual shut-off valve.
4.
Model 56701: Disconnect any wall switch, remote control or
thermostat wires from top & bottom terminals on the gas
valve.
Model 56701-RF: Unplug fan cord from receptacle, discon-
nect the (2) wires from fan cord. (The wires will remain con-
nected to the back of gas valve).
5.
Remove upper hood, upper louver & glass assembly. Refer to
page 37 if necessary.
6.
Remove glass frame assembly. Refer to page 14 if necessary.
7.
Remove logs, pilot shield and bottom refractory panels.
8.
Remove refractory panel set (if installed).
9.
Remove burner tube from firebox by lifting up off tabs, sliding
to left & off the orifice.
10. LP Gas models: Remove LP log plate.
11. Remove and save screws securing front log supports. Remove
log supports.
12. Remove log grate / burner heat shield from fireplace.
13. Remove and save the (6) screws securing the millivolt board to
firebox bottom.
14. Lift millivolt board up and out of firebox being careful not to
damage the sealing gasket lying underneath.
LP GAS MODEL:
LP LOG PLATE
MILLIVOLT BOARD REMOVAL
BURNER TUBE
FRONT LOG SUPPORTS
LOG GRATE / BURNER HEAT SHIELD
PAGE 35
NOTE: Illustrations shown with 56701
valve components.
PILOT SHIELD
REMOVE (6) SCREWS