Displaying Rmon Statistics Information - HP V1910 User Manual

V1910 switch series
Hide thumbs Also See for V1910:
Table of Contents

Advertisement

Item
Interval
Sample
Item
Sample Type
Owner
Create Default
Event
Rising
Threshold
Alarm
Rising Event
Falling
Threshold
Falling Event
Return to
RMON alarm configuration task

Displaying RMON statistics information

Select Device  RMON from the navigation tree to enter the page of the Statistics tab, as shown in a. Click
the
icon of a statistics entry to enter the page as shown in a, which displays all statistics items on the
current interface.
Description
Set the sampling interval.
Set the sampling type, including:
Absolute—Absolute sampling, namely, to obtain the value of the variable
when the sampling time is reached.
Delta—Delta sampling, namely, to obtain the variation value of the variable
during the sampling interval when the sampling time is reached.
Set the owner of the alarm entry.
Select whether to create a default event.
The description of the default event is default event, the action is log-and-trap,
and the owner is default owner.
If there is no event, you can select to create the default event. And when the value
of the alarm variable is higher than the alarm rising threshold or lower than the
alarm falling threshold, the system will adopt the default action, that is,
log-and-trap.
Set the alarm rising threshold.
Set the action that the system will take when the value of the alarm variable is
higher than the alarm rising threshold.
If the Create Default Event check box is selected, this option is not configurable.
Set the alarm falling threshold.
Set the action that the system will take when the value of the alarm variable is
lower than the alarm falling threshold.
If the Create Default Event check box is selected, this option is not configurable.
list.
104

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

V1910-24g-poe (365w)V1910-24g-poe (170w)

Table of Contents