4.3
Changing and Checking the Setting of Detailed FC Card
Information
To increase the stability of connectivity with the ETERNUS series machine, adjust some of the driver
parameters after installing the operating system and driver.
To increase the stability of connectivity with the ETERNUS series machine, adjust some of the driver
parameters after installing the operating system and driver.

4.3.1 Setting driver parameters (for HBAnyware)

1. Click the [Start] button to select [Programs] or [All programs], and then select [Emulex] - [HBAnyware].
HBAnyware starts.
The local server and the HBAs under its control are displayed in the left side of the window. Select the local
server and then click the [Driver Parameters] tab in the right side of the window.
Note
Driver parameters can be set not for the local server but for each HBA. If driver parameters are set for each
HBA, the HBA may be changed due to replacement for maintenance purposes or server switching. In such a
case, the driver parameters are set to the default setting values. As a rule, select the local server and then set the
driver parameters.
2. Set the following driver parameters.
Topology
Queue Depth
Queue Target
Link Speed
For details on the settings required on the ETERNUS when connecting to it, see the ETERNUS manuals at the
following website:
http://www.fujitsu.com/global/services/computing/storage/eternus/documentation/
3. Confirm the settings made so far.
After finishing all the settings, from the [File] menu, select [Exit] to quit HBAnyware.
Then, proceed to 4.4 Checking Registry Information.